Energy · Nuclear

Nuclear facility monitoring

Access limited by dose. Parts age under radiation.

Watts Bar Nuclear Plant cooling towers on the Tennessee River
Watts Bar Nuclear Plant cooling towers on the Tennessee RiverDavid Ratledge · CC BY 4.0

“Capability is a depleting resource to be spent, not a fixed budget to be defended.”

Whitepaper, §5

Monitoring systems in nuclear facilities work where access is limited and parts age under radiation. They need to keep reporting as they degrade.

Mru Field runs on the Linux processor already in the equipment, as three copies of your task. When a copy fails and nobody can come, it continues on the ones left and delivers only results it can check.

What fails out there

01

Parts fail one by one

Radiation, heat and age take out processors and memory. Nothing is replaced until the next visit.

02

Stored data decays

Flash wears out and bits flip. Logs and settings drift unless something checks them. Mru does not check stored data today.

03

No one to ask

When two processors disagree, there is no operator to say which one is right.

What Mru Field does

Three processors. Then two. Then one, still working.

Fixed triple redundancy stops when it loses its majority. Mru Field steps down instead, and says which mode it is in. Each extra processor costs power.

3 alive · vote

ABC

Three processors vote. One bad result is outvoted.

2 alive · compare

ABC

Two compare. On a mismatch, a known-answer test can find the faulty one.

1 alive · self-check

ABC

The last one checks its own work and keeps reporting, at half speed.

Power

Site power

Link

Site network

Visits

Limited by dose and access

Service life

Decades

Questions

Does Mru Field need new hardware?

No. It is software for the Linux processor you already deploy. It runs beside your control code as three replicas of your task and decides which replica to trust as faults appear. Each replica costs processor time. A second processor, which would survive the failure of the first, is planned.

Is Mru Field safety-certified?

Not today. It is for monitoring and non-safety control. Certification would come with a partner.

How do we start?

Use the form below. We first model your hardware and show what each redundancy design returns over its whole life. Then we plan a pilot on your own equipment.

Related settings

More use cases

→ Get in touch

Is Mru Field a fit for your nuclear facility monitoring?

Tell us about the hardware, where it is, and what you need. We will tell you plainly whether Mru fits, including when it does not.

  • We'll review your setup.
  • We'll respond in one business day.
  • No project yet? Say hello.

About: Nuclear facility monitoring

Interested in

We use these details only to reply. No mailing list.